Proper operation and Output from your Prophet system is dependent on the following:
A cable must be fabricated by the installer to
connect the PBX port to the Prophet-H SMDR "Y" cable shown
in the diagram below.
Once all components are connected and power is
applied, perform the test sequence below.
| 1. Press <ESC><CTRL-G> |
This disables PMS
mode |
| 2. Press <ESC> |
Main Menu
appears.
Problem? Press the reset on the Prophet-H.
|
| 3. Press <ESC><SHIFT-#>00
This sets the
Prophet-H to print call records "On the Fly"
to the PC screen. |
Main Menu
then a header appears showing Option 00.
Problem?
|
| 4. Make a one minute
test call and watch the SMDR LED on the Prophet-H front panel
as you hang up. |
The Yellow
SMDR will flash if the PBX has transferred the SMDR.
Problem?
|
| 5. Check the Laptop
screen to see if the call record has been processed correctly. |
Output matching
the format below.
Problem?
|

If the output format is correct, configure
the system for customer use.
|
| Do NOT
type spaces in the commands
that follow, they are placed where a response is expected from
the Prophet-H.
6. Press <ESC> R 1 080 0.01
|
Main Menu,
then location 080 of rate table 1 is changed to a value of 0.01
This places the Prophet-H in "see-thru"
mode. SMDR from the PBX will be sent directly to the SYSTEM
port without processing.
Problem?
|
| 7. Make a one minute
test call and watch the SMDR on the PC screen as you hang up. |
Raw (unprocessed),
but readable SMDR will appear on the screen.
Problem?
|
| 8. Press <ESC>
R 1 080 0.00 |
Main Menu, then
location 080 of rate table 1 is changed back to the default
value of 0.00 turning off "see thru" mode. |
9. Press
<ESC> R 1 081 0.01 082 0.01 083 0.01 |
Main Menu,
then locations 081, 082 and 083 of rate table 1 are changed
to a value of 0.01 turning on "accepted", "rejected"
and "dropped" diagnostics mode.
NOTE: Step 8 must
be completed ("see-thru" turned OFF) for diagnostics
processing. |
| 10. Make a one minute
test call and watch the diagnostics output on the PC screen
as you hang up. |
Output simular
to the format below.
Problem?
|
|
|
| 11. Once proper
output is obtained, press <ESC> 8 1 to reset the Prophet-H
and then configure the system using the Utility software or
direct programming commands.
Go to the General
Programming Reference |
A